Abstract
We investigated the potential sources of error when using time domain reflectometry (TDR) to measure the water content of sandy soils and evaluated the technique as a means of measuring evaporation from columns of soil and changes in soil water storage beneath crops. Inaccurate depth location of the transmission lines or the development of a hole at the tip of the transmission lines introduced an error about 10 times larger than the errors associated with hardware and software. Calibration in two sandy soils gave a curve of similar shape to that found by others except for values of dielectric constant < 6 when measured values of water content were less than those expected. Daily evaporation from soil columns measured by weighing and with TDR showed large differences between the two techniques (up to 32%) but compensating errors over time allowed cumulative evaporation to be estimated with TDR to within 6.6% of that determined by weighing over a 162 h period. Under field conditions, the agreement between TDR and neutron probe measures of changes in soil water storage in the upper 0.3 m was good and generally within 10% over both 14 day and longer periods.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.