In the following case, a 20-year-old male was involved in a motorcycle accident where he sustained an open midshaft femur fracture treated with open reduction and internal fixation. Several weeks later, the wound became infected and the plate was removed. Over the following 20 years numerous incision and debridements were performed, with multiple courses of antibiotics for persisting infection. One year following reaming with the reamer-irrigator-aspirator (RIA), the patient is symptom free. It is our belief that organisms were sequestered in the fibrous and bony tissue at the healed fracture site, and, by opening the canal and allowing it to revascularize, the infection was cleared.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.