Abstract

Prolonged air leak is the major complication after lung reduction surgery for emphysema and the major determinant of hospital length of stay. Twenty-five of 107 patients (24%) (mean age, 66 years) with an average forced expiratory volume in 1 second of 0.55 L experienced a prolonged air leak (>5 days) after lung reduction surgery. These persistent air leaks were treated by replacing the chest drainage system with Heimlich valves to facilitate earlier hospital discharge even though 64% of the patients had apical air spaces that measured 1 to 7 cm. These patients had a mean postoperative stay of 9.1 days. Chest tubes were then removed an average of 7.7 days later. All apical air spaces resolved, and there were no deaths, empyemas, or pneumonias. In conclusion, the use of the Heimlich valve after operation for emphysema was associated with minimal morbidity and shortened the mean hospital stay for patients with prolonged air leaks by 46%. This study demonstrates an important concept in the postoperative management of these patients--do not use suction on severely emphysematous lung.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.