Abstract

The doses from the cobalt-60 teletherapy machines were measured using the FBX and secondary-standard dosemeters of Farmer-Baldwin type. The FBX dosemeter contained 0.20 mM ferrous ammonium sulphate, 5.0 mM benzoic acid and 0.20 mM xylenol orange in 0.5 N sulphuric acid. The values were compared with the values from a Fricke dosemeter and a graphite chamber used as primary standards. The values of the FBX, Fricke and graphite chambers agreed. There were, however wide differences among the different secondary-standard dosemeters themselves and with the FBX dosemeter. The FBX dosemeter was used for the measurement of central axis depth dose distributions for 5, 8, 10, 20 and 30 MeV electron and 42 MV X-ray beams.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.