Abstract
One hundred and two patients undergoing elective abdominal aortic aneurysm repair and admitted to ICU at RPAH in 1989/90 were studied. In forty patients a cell saver was used during the operative procedure (Group CS) while in the remaining sixty-two patients intraoperative blood loss was drained and discarded conventionally (Group NCS). Preoperative ASA grade and postoperative APACHE score were similar in these two groups. The amount of bank blood transfused intraoperatively was less in Group CS than in Group NCS (0.6 +/- 0.2 vs 3.3 +/- 0.3 units) (mean +/- SEM) (P less than 0.0001). The total amount of bank blood transfused during hospital admission was also less in Group CS (1.5 +/- 0.4 vs 4.8 +/- 0.4 units, P less than 0.0001). Of Group CS, 22 patients (55%) received no bank blood compared to two patients (3%) in Group NCS. There was no difference between the groups with respect to postoperative haemoglobin and creatinine levels. ICU stay was similar in both groups. We conclude that use of the cell saver reduces perioperative bank blood transfusion in elective abdominal aortic surgery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.