The Ceretec kit for preparation of 99Tcm-hexamethylpropyleneamine oxime (HMPAO) complex for the investigation of regional cerebral blood flow requires careful handling by the radiopharmacist and a number of restrictions have been placed on the kit relating to the nature of 99Tcm generator eluate used for reconstitution. The addition of sodium iodide to eluate immediately after elution can remove one of these restrictions. A level of 0.4 mg sodium iodide added after elution allows reconstitution of Ceretec up to 6 h later with no adverse effect on radiochemical purity. This offers a simple method for the use of this product if availability of fresh technetium generator eluate is a constraint.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.