Abstract

BackgroundAlong with an aging population, the field of robot technology in rehabilitation is expanding. As new technologies develop, it is important to test these clinically before implementation. To assess the possibilities of undertaking a future randomized controlled trial (RCT), the aim of this study was to pilot test and investigate the feasibility of a newly developed passive mobilization robot device in geriatric medicine patients.MethodsWe used a robot to perform passive mobilization for all recruited patients while they were lying in bed. Inclusion criteria include the following: ≥ 65 years of age, able to walk before hospitalization, and not capable of walking > 2 m at the first day of hospitalization. Exclusion criteria include the following: known moderate/severe dementia, unstable fractures (back, pelvis, or legs), high intracranial pressure, pressure ulcers/risk of developing pressure ulcers due to fragile skin, positive Confusion and Assessment Method (CAM) score, not able to understand Danish, and medical instability. A mixed-methods approach, including structured interviews for patients and relatives, questionnaires and semi-structured interviews for the staff, and observations in the clinic were used as data collection methods. A 6-week pilot test preceded the feasibility study to test study design, safety, interview guide, and setting, and to become familiar with the robot.ResultsThe pilot test included 13 patients, made the staff confident in the use of the robot, and led to the correction of the interview guide. In the feasibility study, 177 patients were screened, 14 patients (four men, nine women) included, and 13 completed the intervention (median [IQR] age 86 [82–92] years). Overall, the robot was easy to use during passive mobilization and fully accepted by patients and relatives. Staff, however, found the robot difficult to maneuver. No adverse events were reported.ConclusionsUse of robot technology in passive mobilization of older patients was feasible and well accepted by patients, relatives, and staff. Technical and workflow-related issues, as well as the robot not performing active mobilization, affects the launch of a RCT and thereby its implementation in geriatric medicine patients.

Highlights

  • Along with an aging population, the field of robot technology in rehabilitation is expanding

  • The pilot test showed that the study design, screening, inclusion, and intervention worked as intended

  • All members of the study board agreed that it was safe for both patients and staff to proceed with the feasibility study

Read more

Summary

Introduction

Along with an aging population, the field of robot technology in rehabilitation is expanding. To assess the possibilities of undertaking a future randomized controlled trial (RCT), the aim of this study was to pilot test and investigate the feasibility of a newly developed passive mobilization robot device in geriatric medicine patients. Acute hospitalization is often accompanied by a reduced level of physical activity, and studies show that older patients spend most of their time lying passively in bed [3,4,5]. Bertelsen et al Pilot and Feasibility Studies (2020) 6:1 acute illness and hospitalization [7, 8]. This makes mobilization of older hospitalized adults an important issue to address in acute rehabilitation research

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.