Abstract

When sufficient data are available, the statistical power of a test can be determined using power analysis procedures. The term “detectable significance” has been coined to refer to this criterion based on power analysis and past performance of a test. This power analysis procedure has been performed with sea urchin ( Arbacia punctulata) fertilization and embryological development data from sediment porewater toxicity tests. Data from 3100 and 2295 tests for the fertilization and embryological development tests, respectively, were used to calculate the criteria and regression equations describing the power curves. Using Dunnett’s test, a minimum significant difference (MSD) ( β=0.05) of 15.5% and 19% for the fertilization test, and 16.4% and 20.6% for the embryological development test, for α≤0.05 and α≤0.01, respectively, were determined. The use of this second criterion reduces type I (false positive) errors and helps to establish a critical level of difference based on the past performance of the test.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.