Abstract
A platelet-fibrinogen-thrombin mixture utilizing autologous platelets was studied for its potential to seal perforating corneal wounds. In rabbits, the mixture demonstrated sufficient adhesive properties to permit 75% of penetrating keratoplasties to remain in place without the use of sutures. All 12 grafts held initially; after 48 h three grafts extruded. In control eyes only two out of 12 (16%) of the corneal grafts remained in place. The material is simple to prepare and apply and is not toxic to the cornea. It does not cause inflammation or lid irritation. Intraocular complications observed with its use were transient anterior synechiae and retrocorneal membrane formation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Albrecht von Graefes Archiv f�r Klinische und Experimentelle Ophthalmologie
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.