Abstract

Current ultrasound (US) Doppler techniques cannot demonstrate the vascularization of the dermis. The purpose of this study was to investigate whether the new Superb Vascular Imaging (SMI) and Microvascular Flow (MV-Flow) techniques improve the detection of normal dermis vessels. SMI and MV-Flow were compared side-by-side to conventional power-Doppler (PD) imaging. By using US, 50 healthy volunteers were evaluated at level of five body areas: forehead, forearm, palm, buttock, and thigh. Two off-site operators evaluated the images to assess the difference between SMI and PD imaging and between MV-Flow and PD imaging in terms of dermis flow amount. A 0-3 scoring system was adopted. SMI scored grade 0 in 0% of body areas, grade 1 in 58%, grade 2 in 33%, and grade 3 in 9%. In comparison with SMI, PD scored grade 0 in 38% of body areas, grade 1 in 56%, grade 2 in 6%, and grade 3 in 0%. MV-Flow scored grade 0 in 0% of body areas, grade 1 in 52%, grade 2 in 43%, and grade 3 in 6%. Comparted to MV-Flow, PD scored grade 0 in 53% of body areas, grade 1 in 34%, grade 2 in 13%, and grade 3 in 0%. The difference in terms of sensitivity was statistically significant for all the body areas investigated. We found bothSMI and MV-Flow to be superior to PD imaging and capable to demonstrate normal vascularization of the dermis.