Abstract

We report a method for determining total chromium in tanning samples using sequential injection analysis (SIA) with a diode-array spectrophotometric detector. With a suitable analytical sequence CrO4(2-) is converted to Cr2O7(2-) inside the tubes of the SIA system, after total oxidation of chromium(III). A data matrix is obtained and analysed by several chemometric techniques based on multivariate analysis: principal components analysis, simple-to-use interactive self-modelling mixture analysis, and multivariate curve resolution-alternating least-squares. We studied several samples from different stages of a tanning process. Two of these samples were easily oxidized but the others needed more extreme conditions. The analytical sequence prepared, which was based on obtaining a pH gradient and used H2SO4 as reagent, is valid and independent of the level of oxidation needed for the sample. We established a calibration model and evaluated the figures of merit. In some samples we found interferents. With this method the amounts of chromium in each sample were quantified and the results were statistically similar to those obtained by use of the reference method, atomic absorption spectrometry.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.