Abstract

A three-dimensional treatment planning system capable of gantry, collimator, and table rotations is required for a noncoplanar conformal therapy. Unfortunately, such a system is not widely available. A method in which multiplanar reformatted radiographic (MPR) and digitally reconstructed radiographic (DRR) images are used is presented for conformal treatment of brain tumors. A head phantom containing a target volume was scanned on a computed tomographic (CT) simulator. The coronal MPR images were digitized on a treatment planning system to create a conformal block of the planned treatment field. The DRR images were generated on the CT simulator with the setup parameters calculated from the treatment planning system. A second set of conformal blocks was generated based on DRR images of the fields. The accuracy of the MPR- and DRR-generated blocks was verified on the vertex field. The differences between the actual planning target volume and the field edges of the MPR and DRR blocks were within +/- 4 mm and +/- 2 mm, respectively. The authors conclude that the MPR and DRR images could be successfully used to generate conformal blocks and for treatment planning of noncoplanar beams in radiation therapy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call