Abstract

Continuous fixed-bed studies were undertaken to evaluate the performance of manganese oxide-coated sand (MOCS) as an adsorbent for the removal of uranium(VI) ions from aqueous solution under the effect of various process parameters such as the bed depth, the flow rate, the presence of salt and the initial U(VI) ion concentration. The U(VI) ion uptake by MOCS increased with initial U(VI) ion concentration and bed height, but decreased as the flow rate increased. A shorter breakthrough time was observed in the presence of salt. The experimental data obtained from the breakthrough curves were analyzed using the Thomas model. The BDST model was also applied to predict the service times for other flow rates and initial concentrations. The results showed that the Thomas model was suitable for the description of the whole breakthrough curve, while the data were in good agreement with the BDST model. The columns were regenerated by eluting the bound U(VI) ions with 0.5 mol/l HNO3 solution after the adsorption stu...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.