Abstract

BackgroundThe hemodynamic status of newborns with intracranial arteriovenous shunts (AVSs) may be extremely complex. Mini-invasive hemodynamic monitoring through innovative techniques such as Near-Infrared Spectroscopy (NIRS) and Pressure Recording Analytical Method (PRAM) may help in understanding hemodynamics in newborns with AVSs. Levosimendan is a calcium sensitizer and inodilator, and it is known to improve ventricular function, but its use in newborns is limited. In our cases, we evaluated the effect of levosimendan on hemodynamics through NIRS and PRAM.Case presentationHerein, we report the cases of two neonates with intracranial arteriovenous shunts, in whom we used levosimendan to manage cardiac failure refractory to conventional treatment. Levosimendan was used at a dosage of 0.1 mcg/kg/min for 72 h. Combined use of NIRS and PRAM helped in real-time monitoring of hemodynamic effects; in particular, levosimendan determined significant improvement in myocardium contractility as well as a reduction of heart rate.ConclusionIn two neonatal cases of AVSs, levosimendan led to an overall hemodynamic stabilization, documented by the combination of NIRS and PRAM. Our results suggest introducing levosimendan as a second-line treatment in cases of severe cardiac dysfunction due to AVSs without improvement using standard treatment strategies. Future prospective and larger studies are highly warranted.