Abstract

Proper femoral and acetabular component position and leg length equality are important intraoperative considerations during total hip arthroplasty. Unfortunately, traditional surgical techniques often lead to suboptimal component position, and such deviations have been associated with increased rates of prosthetic wear, dislocation, component loosening, and patient dissatisfaction. Although surgical navigation has been shown to improve reproducibility of component alignment, such technology is not universally available and is associated with significant costs and additional surgical/anesthetic time. In the current study, we found that a routine intraoperative pelvic radiograph could successfully identify malpositioned components and leg length inequalities and could allow for successful correction of identified problems. Unexpected component malposition and leg length inequality occurred in only 1.5% of cases where an intraoperative pelvic radiograph was utilized.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.