Abstract

This study evaluated practices for image guidance during placement of bicaval dual-lumen (BCDL) venovenous extracorporeal membrane oxygenation (VV-ECMO) cannulas in pediatric and adolescent patients and elucidates reasoning behind surgeon practices. A survey covering VV-ECMO practice and opinions was distributed by the American Pediatric Surgical Association (APSA) to all attending members. A total of 110 pediatric surgeons responded (11.3%). During initial BCDL cannula placement, 67.7% of surgeons reported using bimodal imaging with either fluoroscopy (38.4%) or x-ray (29.3%) plus echocardiography. Although 37.4% of surgeons used serial x-rays during cannula placement, only 5.9% believed it was best practice to do so ( P < 0.0001). Rather, 60.4% believed that fluoroscopy was the standard. Among surgeons not using fluoroscopy, 27.6% (13.3% of respondents) reported fluoroscopy added unnecessary complexity or that they preferred another modality. More frequently, reasons for not using fluoroscopy are related to resource limitations. Echocardiography use to confirm cannula position was considered best practice by 92.1% of surgeons, with 86.9% utilization. Therefore, most pediatric surgeons use multimodal imaging during cannulation and consider it best practice. Fluoroscopy is preferred, but its use is frequently limited by hospital resources. Echocardiography is widely available and used. These data represent increased consensus among surgeons and present opportunities for modernization of hospital resources and standards.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call