Abstract

Emergency neonatal resuscitation equipment is often organized into "code carts". Simulation studies previously examined human factors of neonatal code carts and equipment; however, visual attention analysis with eye-tracking might further inform equipment design. To evaluate human factors of neonatal resuscitation equipment by: (1) comparing epinephrine preparation speed from adult pre-filled syringe vs. medication vial, (2) comparing equipment retrieval times from two carts and (3) utilizing eye-tracking to study visual attention and user experience. We conducted a 2-site randomized cross-over simulation study. Site 1 is a perinatal NICU with carts focused on airway management. Site 2 is a surgical NICU with carts improved with compartments and task-based kits. Participants were fitted with eye-tracking glasses then randomized to prepare two epinephrine doses using two methods, starting with an adult epinephrine prefilled syringe or a multiple access vial. Participants then obtained items for 7 tasks from their local cart. Post-simulation, participants completed surveys and semi-structured interviews while viewing eye-tracked video of their performance. Epinephrine preparation times were compared between the two methods. Equipment retrieval times and survey responses were compared between sites. Eye-tracking was analyzed for areas of interest (AOIs) and gaze shifts between AOIs. Interviews were subject to thematic analysis. Forty HCPs participated (20/site). It was faster to draw the first epinephrine dose using the medication vial (29.9s vs. 47.6s, p < 0.001). Time to draw the second dose was similar (21.2s vs. 19s, p = 0.563). It was faster to obtain equipment from the Perinatal cart (164.4s v 228.9s, p < 0.027). Participants at both sites found their carts easy to use. Participants looked at many AOIs (54 for Perinatal vs. 76 for Surgical carts, p < 0.001) with 1 gaze shifts/second for both.Themes for epinephrine preparation include: Facilitators and Threats to Performance, and Discrepancies due to Stimulation Conditions. Themes for code carts include: Facilitators and Threats to Performance, Orienting with Prescan, and Suggestions for Improvement. Suggested cart improvements include: adding prompts, task-based grouping, and positioning small equipment more visibly. Task-based kits were welcomed, but more orientation is needed. Eye-tracked simulations provided human factors assessment of emergency neonatal code carts and epinephrine preparation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call