Abstract

Interaction of carbon monoxide with CNx catalysts was investigated using pulse chemisorption, DRIFTS, and cyclic voltammetry techniques. Pulsed chemisorption experiments showed no CO uptake over the CNx catalysts. Cyclic voltammetry and potential hold studies showed carbon monoxide not to have any electrocatalytic interaction with nitrogen-doped graphite surfaces and not to have any poisoning effect for the oxygen reduction reaction. This is in contrast to the preferential adsorption of CO in the presence of oxygen on ORR sites of Pt catalysts, inhibiting the oxygen reduction activity drastically. Cyanide poisoning experiments performed using KCN showed no activity loss for CNx, while Pt/VC catalysts showed significant deactivation. These studies suggest that it is unlikely for coordinated metal sites to have significant contribution to the oxygen reduction reaction in CNx catalysts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.