Abstract

Abstract : A series of B/epoxy-A1 double lap shear specimens were prepared and exposed to high humidity and temperature. Half of these were prepared using the commercial DynCorp process used for bonded repair of aircraft. The other half was prepared using a modified process to reduce durability. Electrochemical impedance spectroscopy (EIS) measurements were taken on these specimens using a patented DACCO SCI sensor. A set of these specimens was mechanically tested each month to determine pull strength. The EIS impedance spectra were analyzed using equivalent circuit analysis. Several circuit parameters upon exposure to moisture. Changes in the capacitance allowed moisture uptake to be calculated. By placing the sensor electrodes in different locations, variations in moisture concentration in the bonded system can be determined. This approach provides advance warning before any significant reduction of bond strength. Thus, it has the potential to monitor adhesively bonded repair patches and allow preventative maintenance prior to any degradation of bond performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.