Abstract

Following the opening of an infant cardiac neonatal intensive care unit, our aim was to determine a baseline UE rate and implement initiatives to target a goal less than 0.5 UEs/100 ventilator days. We utilized the Model for Improvement. Key stakeholders included neonatal providers, nurses, and respiratory therapists. We focused on the creation of an airway bundle that addressed securement methods, communication and education. From October 2017 to January 2018, our baseline UE rate was 0.92 UEs/100 ventilator days. Subsequent to the implementation of an airway bundle with high compliance, we observed a significant change in the centerline (0.45 to 0.02 UEs/100 ventilator days) during the spring of 2021, followed by a period of 480 days with no UEs. In a unit where UEs were infrequent events, high compliance with an airway bundle led to a significantly sustained decrease in our UE rates.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.