Abstract

To determine the safety and efficacy of amniotic membrane graft in glaucoma drainage device surgery. Institutional retrospective case series of 44 patients undergoing glaucoma drainage device implantation with use of 300-μm thick amniotic membrane as a patch graft. Endpoints assessed were tube exposure, graft thinning, graft clarity, graft-related infection, and inflammation. A total of 41 (93%) eyes had an uneventful course over a mean follow-up of 22 ± 3 months (range: 17 to 28 months). Tube exposure and hypotony each occurred in one eye and were successfully treated with a tube revision using double pericardial and amniotic membrane patch graft. The translucency of amniotic membrane graft enabled good visualization of the occluding suture when performing laser suture lysis in 16 eyes. Sequential anterior segment optical coherence tomography showed stable amniotic membrane graft thickness with a change from low to moderate reflectivity in the subconjunctival-graft bilayer. Amniotic membrane graft offers good tectonic support and allows direct visualization of the underlying tube.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.