Abstract

BackgroundAssessment of the patient’s respiratory effort is essential during assisted ventilation. We aimed to evaluate the accuracy of airway pressure (Paw)-based indices to detect potential injurious inspiratory effort during pressure support (PS) ventilation.MethodsIn this prospective diagnostic accuracy study conducted in four ICUs in two academic hospitals, 28 adult acute respiratory failure patients undergoing PS ventilation were enrolled. A downward PS titration was conducted from 20 cmH2O to 2 cmH2O at a 2 cmH2O interval. By performing an end-expiratory airway occlusion maneuver, the negative Paw generated during the first 100 ms (P0.1) and the maximal negative swing of Paw (∆Pocc) were measured. After an end-inspiratory airway occlusion, Paw reached a plateau, and the magnitude of change in plateau from peak Paw was measured as pressure muscle index (PMI). Esophageal pressure was monitored and inspiratory muscle pressure (Pmus) and Pmus–time product per minute (PTPmus/min) were used as the reference standard for the patient’s effort. High and low effort was defined as Pmus > 10 and < 5 cmH2O, or PTPmus/min > 200 and < 50 cmH2O s min−1, respectively.ResultsA total of 246 levels of PS were tested. The low inspiratory effort was diagnosed in 145 (59.0%) and 136 (55.3%) PS levels using respective Pmus and PTPmus/min criterion. The receiver operating characteristic area of the three Paw-based indices by the respective two criteria ranged from 0.87 to 0.95, and balanced sensitivity (0.83–0.96), specificity (0.74–0.88), and positive (0.80–0.91) and negative predictive values (0.78–0.94) were obtained. The high effort was diagnosed in 34 (13.8%) and 17 (6.9%) support levels using Pmus and PTPmus/min criterion, respectively. High receiver operating characteristic areas of the three Paw-based indices by the two criteria were found (0.93–0.95). A high sensitivity (0.80–1.00) and negative predictive value (0.97–1.00) were found with a low positive predictive value (0.23–0.64).ConclusionsBy performing simple airway occlusion maneuvers, the Paw-based indices could be reliably used to detect low inspiratory efforts. Non-invasive and easily accessible characteristics support their potential bedside use for avoiding over-assistance. More evaluation of their performance is required in cohorts with high effort.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call