Abstract

The number of patients requiring revision total hip arthroplasty continues to increase each year. Accurate preoperative planning is a key factor in obtaining a good result. Radiographis provide little information concerning the actual extent of the acetabular defects. Computed tomography-generated models ofthe acetabulium can provide the surgeon with accurate information concerning the size and location of the defects. Evaluation of radiographs and models in 24 cases showed that radiographs alone failed to detect all 13 anterior wall defects ( P < .001), 8 of 18 posterior wall defects (44.4%, P < .001), and 8 of 19 segmental central defects (42%, P < .001), all of which were easily identified with the models. This study showed that preoperative planning based on the foam models accurately predicted the actual implant used in 22 of 24 cases (92%).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.