Abstract

A technique for reconstruction of the thoracic esophagus was evaluated in 13 dogs. A 9 x 10 cm section of transversus abdominis muscle was harvested, fashioned into a tubular graft, and vascularized via the greater omentum. The vascularized tube was advanced into the caudal thorax through the diaphragm at a second surgery 20 to 44 days after harvesting the section of the transversus abdominis muscle. A 5 cm section of caudal thoracic esophagus was replaced with the vascular tubular graft. One dog died because of incarceration of the intestine within the tube and two dogs were euthanized because of infected tubes. One dog died due to an anesthetic complication, one dog had a diaphragmatic hernia and died, and one dog died from pyothorax. Leakage of luminal contents at the anastomoses did not occur in any dog. Seven dogs survived both surgeries but showed deglutitory difficulty 6 days postoperatively due to the grafted esophageal segments becoming severely strictured in each case. Angiography demonstrated vascularization of the full thickness of the graft in each of the seven dogs. An unacceptably high incidence of infection and stricture formation made this technique unsuitable for clinical use.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.