Abstract

The authors placed titanium mesh cages to achieve posterior atlantoaxial fixation in five patients with atlantoaxial instability caused by rheumatoid arthritis or os odontoideum. A mesh cage packed with autologous cancellous bone was placed between the C-1 posterior arch and the C-2 lamina and was tightly connected with titanium wires. Combined with the use of transarticular screws, this procedure provided very rigid fixation. Solid fusion was achieved in all patients without major complications. The advantages of this method include more stable fixation, better control of the atlantoaxial fixation angle, and reduced donor-site morbidity compared with a conventional atlantoaxial arthrodesis in which an autologous iliac crest graft is used.