Abstract

To investigate the use of a locking 3.5/4.0-mm jumbo tibial plateau leveling osteotomy (TPLO) plate in maintaining the postoperative tibial plateau angle (TPA) in giant-breed dogs weighing > 50 kg and to report the associated complications. Canine patients weighing > 50 kg that underwent TPLO stabilized with a locking 3.5/4.0-mm jumbo TPLO plate between January 2017 and May 2022. Retrospective case series retrieving postoperative outcomes from the medical records. Healing scores and TPAs were calculated using postoperative and recheck radiographs. Owner-perceived outcomes were obtained via questionnaire. 24 stifles in 22 dogs were included. Postoperative complications were recorded in 11 of 24 cases (45.8%) inclusive of 1 minor, 1 catastrophic, and 9 major complications. A statistically significant increase in TPA over the convalescent period was found. Grade 4 healing was present in 18 of 24 (75%) stifles, while the remainder were scored as grade 3. The use of a locking 3.5/4.0-mm jumbo TPLO plate did not prevent a statistically significant increase in TPA through convalescence. This procedure displayed an unacceptably high complication rate when compared with contemporary literature of TPLO. Despite a high complication rate in this patient population, most complications were successfully managed with medical and/or surgical treatment, and high mean and median healing scores were achieved at the radiographic recheck. Additionally, owner-perceived long-term outcomes were excellent.