Abstract

An unusual property of salt water, that is its ability to inhibit air bubble coalescence, has been used as the basis for a new method of water sterilization. In this process, high-temperature gas is passed through a porous sinter into a contaminated aqueous solution containing at least 0.15M NaCl, to prevent bubble coalescence. It is found that even at high gas temperatures, the presence of salt still inhibits bubble coalescence and hence high bubble volume fractions of small bubbles can be attained, which is shown to improve the efficiency of the sterilization process. It has been established that the continuous flow of hot (dry) gases, even at 150°C, only heat the aqueous solution to about 45°C, which is an ideal temperature for bacterial colony growth in typical contaminated water. Hence, it has been established that sterilization occurs due to the transient collision of biological species with the hot gas bubbles. This new method has a significantly improved energy efficiency over the standard process of sterilization of boiling the contaminated water for 5–30 min, as typically recommended.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.