Abstract

Abstract Investigations were undertaken at two small farm dairies noted to have sporadic failures of statutory phosphatase tests on samples of cream. Bottled whole milk and skimmed milk from both dairies appeared to be satisfactory. Use of the highly sensitive fluorimetric phosphatase test enabled us to demonstrate that diversion of heat-treated whole milk to a separator resulted in under-pasteurisation. This was due to increased flow rate through the holding tube and was confirmed by a simple timing experiment. Modification of high-temperature-short-time pasteurisers in order to produce a range of products may affect the dynamics of flow resulting in inadequate heat-treatment and possibly in survival of microbial pathogens.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.