Abstract

SUMMARYDuring surgical procedures involving the mandible, preserving the inferior alveolar nerve (IAN) may be preferable for benign tumours. In this prospective pilot study, we report our experience on the use of a Rapid Inferior Alveolar nerve Customised Salvage (RICS) template. Virtual surgical planning (VSP) of the template is based on a 3D model obtained from the elaboration of DICOM files of the preoperative CT scan. Five patients affected by benign mandibular pathology were included. A total of 7 IANs were exteriorised. The average time of exteriorisation was 23 minutes. All exteriorisations were performed successfully and no damage to the neuro-vascular bundle occurred. All patients showed complete recovery of sensitivity of the IAN within 7 weeks after surgical procedure. In conclusion, RICS template seems to allow faster and safer exteriorisation of the IAN.