Abstract

Purpose: We developed a method for ureteral stent exchange in female patients under fluoroscopic guidance using a crochet hook technique (CHEX). Patients and Methods: A total of 45 female patients (51 stents) underwent exchange of ureteral stents. In these patients, 21 ureteral stents were exchanged using CHEX. All procedures were carried out with the patients under conscious sedation. At the time of the procedures, we extracted the ureteral stent from the external urethral orifice using CHEX under fluoroscopic guidance and inserted the new stent under fluoroscopic guidance without cystoscopy. Results: 20 of the 21 stents (95.2%) were successfully exchanged. Ureteral stent exchange using CHEX was unsuccessful in 1 patient, including migration to the ureter. Conclusions: Ureteral stent exchange using a crochet hook is easy, safe and cost-effective. This technique was also easy to learn.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.