Abstract

Upward gas-liquid flow through vertical concentric and fully eccentric annuli was studied both experimentally and theoretically. A flow system was designed and constructed for this study. The system consists of a 16-m long vertical annulus with 76.2-mm i.d. casing and 42.2-mm o.d. tubing. A comprehensive experimental investigation was conducted for both concentric and fully eccentric annuli configurations, using air-water and air-kerosene mixtures as the flowing fluids. Included were definition and classification of the existing flow patterns and development of flow pattern maps. Measurements of volumetric average liquid holdup and average total pressure gradient were made for each flow pattern for a wide range of flow conditions. Additional data include single-phase friction factor values and Taylor bubble rise velocities in a stagnant liquid column. Data analysis revealed that application of the hydraulic diameter concept for annuli configurations is not always adequate, especially at low Reynolds number flow conditions. A more rigorous approach was thus required for accurate prediction of the flow behavior, especially for two-phase flow. Part I of the study includes experimental data and analyses of single-phase friction factor, Taylor bubble rise velocity, and flow pattern transition boundaries.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call