Abstract

AbstractThe removal of lead and zinc from a binary solution by fixed bed depths (40, 80 and 120 mm) of a natural zeolite was examined at a flow rate of 1 mL/min. The results obtained were fitted to the Bed Depth Service Time (BDST) model and the parameters of the model (q and k) were used to design a column system for flow rates of 2 and 3 mL/min at a bed depth of 80 mm. The experimental results were in excellent agreement with those predicted and experimental breakthrough curves for the binary systems were obtained. This approach facilitates the design of effective binary column processes without additional experimentation. Two major design parameters, the Empty Bed Contact Time (EBCT) and the zeolite usage rate, were calculated. The highest EBCT value of 13.56 min represents the optimal conditions for the binary (Pb+Zn) solution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.