Abstract

Venus Express SOIR terminator profiles of CO2 densities and corresponding temperatures have been determined for 132 selected orbits obtained between 2006 and 2013. These recently recalibrated measurements provide temperature profiles at the Venusian terminator over approximately 70–160km, revealing a striking permanent temperature minimum (at about 125km) and a weaker temperature maximum (over 100–110km). In addition, topside temperatures (above 140km) reveal a warming trend consistent with a typical thermospheric structure. These features are reflected in the corresponding CO2 density profiles, and provide detailed constraints for global circulation models of the upper atmosphere.New Venus Thermospheric General Circulation Model (VTGCM) simulations are presented for conditions appropriate to these SOIR measurements. In particular, solar minimum to moderate fluxes are specified and mean values of eddy diffusion and wave drag parameters are utilized. Recent upgrades to the VTGCM code now include more realistic lower boundary conditions at ~70km near cloud tops. Model temperature profiles are extracted from the terminators that correspond to five latitude bins presently used in the SOIR data analysis. Averaging of VTGCM temperature profiles in each of these bins (at each terminator) is conducted to match SOIR sampling. Comparisons of these SOIR and VTGCM temperature profiles are shown. Most notably, the observed temperature minimum near 125km and the weaker temperature maximum over 100–110km are generally reproduced by the VTGCM at the correct pressure/altitude levels. However, magnitudes of simulated and measured temperatures are somewhat different as a function of latitude. In addition, VTGCM evening terminator (ET) temperatures are simulated to be modestly warmer than corresponding morning terminator (MT) values, a result of stronger ET than MT zonal winds at/above about 130km. The SOIR terminator temperatures thus far do not reveal this consistent trend, suggesting the VTGCM climate based winds may not precisely represent the averaged conditions during SOIR sampling. Overall, these data-model comparisons reveal that both radiative and dynamical processes are responsible for maintaining averaged temperatures and driving significant variations in terminator temperature profiles.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.