Abstract

We developed and validated a fast UPLC-MS/MS method with positive electrospray ionization (ESI+) for the quantitative determination of S-nitrosoglutathione (GSNO) in human plasma. We used a published protocol for the inactivation of plasma γ-glutamyltransferase (γGT) activity by using the γGT transition inhibitor serine/borate and the chelator EDTA for the stabilization of GSNO, and N-ethylmaleimide (NEM) to block SH groups and to avoid S-transnitrosylation reactions which may diminish GSNO concentration. S-[(15)N]Nitrosoglutathione (GS(15)NO) served as internal standard. Fresh blood was treated with NEM/serine/borate/EDTA, plasma spiked with GS(15)NO (50nM) was ultrafiltered (cut-off 10kDa) and 10μL aliquots of the ultrafiltrate were analyzed by UPLC-MS/MS. Five HILIC columns and an Acquity UPLC BH amide column were tested. The mobile phase was acetonitrile-water (70:30, v/v), contained 20mM ammonium formate, had a pH value of 7, and was pumped isocratically (0.5mL/min). The Nucleoshell column allowed better LC performance and higher MS sensitivity. The retention time of GSNO was about 1.1min. Quantification was performed by selected-reaction monitoring the mass transition m/z 337 ([M+H](+))→m/z 307 ([M+H(14)NO](+)) for GSNO (i.e., GS(14)NO) and m/z 338 ([M+H](+))→m/z 307 ([M+H(15)NO](+)) for GS(15)NO. NEM/serine/borate/EDTA was found to stabilize GSNO in human plasma. The method was validated in human plasma (range, 0-300nM) using 50nM GS(15)NO. Accuracy and precision were in generally acceptable ranges. A considerable matrix effect was observed, which was however outweighed by the internal standard GS(15)NO. In freshly prepared plasma from heparinized blood donated by 10 healthy subjects, no endogenous GSNO was determined above 2.8nM, the limit of quantitation (LOQ) of the method. This study challenges previously reported GSNO plasma concentrations being far above the present method LOQ value and predicts that the concentration of low-molecular-mass and high-molecular-mass S-nitrosothiols are in the upper pM- and lower nM-range, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.