Abstract

Beijing Synchrotron Radiation Facility is a partly dedicated synchrotron radiation source operated in either parasitic or dedicated mode. The 3B1A beamline, extracted from a bending magnet, was originally designed as a soft x-ray beamline for submicro x-ray lithography with critical lateral size just below 1μm in 1988 and no change has been made since it was built. But later the required resolution of x-ray lithography has changed from sub-micrometre to the nanometre in the critical lateral size. This beamline can longer more meet the requirement for x-ray nano lithography and has to be modified to fit the purpose. To upgrade the design of the 3B1A beamline for x-ray nano lithography, a mirror is used to reflect and scan the x-ray beam for the nano lithography station, but the mirror's grazing angle is changed to 27.9mrad in the vertical direction and the convex curve needs to be modified to fit the change; the tiny change of mirror scanning angle is firstly considered to improve the uniformity of the x-ray spot on the wafer by controlling the convex curve.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.