Abstract
For the 1.5GeV energy injector upgrade project for the NSRRC synchrotron light source, new ramping power supplies were implemented in the “White circuit” booster synchrotron ring. IGBT semiconductors operating at a higher frequency was employed to replace the older GTO-based system. The new system enabled reduction of the current waveform harmonic distortions and thus improving the injection and extraction efficiency. The increased reliability increased blind power from circuit mistuning also ensures higher system uptimes. The measured dynamic range of the 10 Hz sine wave current output of the new ramping power supply is shown to be better than 75 dB with a total harmonic distortion (THD) less than 0.015 %. From the monitored beam current, the low THD dipole magnets current can greatly improve the stability of the booster beam current.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.