Abstract

In this study, wastewater from a centrifuge rubber latex concentration unit was experimentally treated by an up-flow anaerobic filter (UAF) at variable hydraulic detention time to investigate the COD removal efficiency and the gas production rate. The UAF reactors were made of PVC pipe with an inside diameter of 9.5 cm, 180 cm in height, with a bed volume of 12.8 L, and filled with polyethylene media. The initial COD concentration of wastewater was in the range 4620 - 10400 mg.L-1. HRTs were controlled at 20 days, with the organic loading rate varying from 2.9 to 10.5 kg.day.m-3. The findings show that the COD removal efficiency of the system was in the range of 85% to 92% for the varying organic loading rates. In addition, the specific methane production rate varied from 8.2 to 14 L of CH4 produced/g of COD destroyed/day for the different organic loading rates.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.