Abstract

Nowadays, low power factor (PF) is a serious problem that has gained more importance in power electronics area. In this study, a unity PF control (UPC) strategy for boundary conduction mode (BCM) buck–buck/boost PF correction converter is proposed. The proposed control strategy can achieve high PF and low total harmonic distortion by utilising the input and output voltages to modulate the on-time of both buck and buck/boost switches. The operating principles and comparative analysis of BCM buck–buck/boost converter with conventional non-UPC and UPC are analysed. For verifying the effectiveness of the proposed control strategy, the experimental verifications are carried out from a 100 W universal input prototype.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call