Abstract
The real-time control of wave energy converters (WECs) requires the prediction of the wave elevation at the location of the device in order to maximize the power extracted from the waves. One possibility is to predict the future wave elevation by combining its past history with the spatial information coming from a sensor which measures the free surface elevation up-wave of the WEC. As an application example, this paper focuses on the prediction of the wave elevation inside the chamber of the oscillating water column (OWC) for the Pico OWC plant in the Azores, and two different sensors for the measurement of the free surface elevation up-wave of the OWC were tested. The study showed that the use of the additional information coming from the up-wave sensor does not significantly improve the linear prediction of the chamber wave elevation given by a forecasting model based only on the past values of the chamber wave elevation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.