Abstract

Most pathological pain conditions in patients and rodent pain models result in marked alterations in mechanosensation and the gold standard way to measure this is by use of von Frey fibers. These graded monofilaments are used to gauge the level of stimulus-evoked sensitivity present in the affected dermal region. One of the most popular methods used to determine von Frey thresholds is the up–down testing paradigm introduced by Dixon for patients in 1980 and by Chapman and colleagues for rodents in 1994. Although the up–down method is very accurate, leading to its widespread use, defining the 50% threshold from primary data is complex and requires a relatively time-consuming analysis step. We developed a computer program, the Up–Down Reader (UDReader), that can locate and recognize handwritten von Frey assessments from a scanned PDF document and translate these measurements into 50% pain thresholds. Automating the process of obtaining the 50% threshold values negates the need for reference tables or Microsoft Excel formulae and eliminates the chance of a manual calculation error. Our simple and straightforward method is designed to save research time while improving data collection accuracy and is freely available at https://sourceforge.net/projects/updownreader/ or in supplementary files attached to this manuscript.

Highlights

  • Touch is one of our most utilized senses, often so ubiquitous that we forget that we continuously process information this way while conscious

  • To streamline the calculation of the mechanical sensory thresholds following data acquisition, we have developed a computer program that can locate and recognize handwritten von Frey assessments from a scanned PDF document and translate these measurements into 50% pain thresholds based on the up–down method

  • The contents of each cell within a table are classified as X, O, or empty, and the program groups the values within each defined table as string sequences

Read more

Summary

Introduction

Touch is one of our most utilized senses, often so ubiquitous that we forget that we continuously process information this way while conscious. Cutaneous sensitivity testing with von Frey filaments provides a quantitative measurement of sensory threshold. To streamline the calculation of the mechanical sensory thresholds following data acquisition, we have developed a computer program that can locate and recognize handwritten von Frey assessments from a scanned PDF document and translate these measurements into 50% pain thresholds based on the up–down method.

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.