Abstract
The temperature inferential control of two alternate designs of the double feed ideal reactive distillation (RD) column is studied. Controlling the most sensitive tray temperature in the first design causes the control system to succumb to non-linear dynamic phenomena for large throughput changes. For the two control structures studied, the second design handles larger throughput changes. A bifurcation study implicates input multiplicity for the observed non-linear dynamic phenomena in the two designs. For good controllability, the need for designing a column with high tray temperature sensitivity and mitigating input multiplicity is highlighted.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.