Abstract

Capsule endoscopy (CE) is a convenient and promising alternative endoscopic method for the gastrointestinal diagnostics on clinical sites; however, multifunctional utilization with active targeting locomotion is still challenging due to internal power limitations and micro-size manipulation mechanisms. The biopsy is one of the most demanding functions of intestinal CE, and successful developments could significantly improve the intestinal diagnostics for precise decisions and comfortable usage. In this paper, we present a novel active locomotive robotic biopsy capsule endoscope using an externally driven electromagnetic actuation (EMA) system and a battery-free wireless rotating blade mechanism. The external magnetic field from the EMA system controls both locomotion and biopsy operation, and thus, the proposed mechanism does not consume the internal power of the CE. We prototyped the proposed biopsy module and integrated it into an active locomotive capsule endoscope. Simulations were conducted to design the module and analyze the magnetic responses. We performed experiments with the biopsy capsule endoscope both in vitro and ex vivo to demonstrate its feasibility. In conclusion, the prototyped robotic biopsy capsule endoscope could successfully perform the necessary movements for the capsule in the small intestine and perform a biopsy at the target lesion with sufficient force. The amount of biopsy tissue was sufficient for a histological examination.

Highlights

  • In 2000, wireless capsule endoscopy (WCE) was introduced as a potential method to visualize and examine the lining of the digestive tract

  • Owing to the interaction between the magnet inside active locomotive intestinal capsule endoscope (ALICE) and the dynamic magnetic field produced by electromagnetic actuation (EMA), ALICE can provide active locomotion and biopsy operation that will be introduced in later part of this paper

  • A rotating cylindrical permanent magnet with radial magnetization inside the capsule interacted with the non-uniform magnetic field produced by the EMA system to move

Read more

Summary

Introduction

In 2000, wireless capsule endoscopy (WCE) was introduced as a potential method to visualize and examine the lining of the digestive tract. An active locomotive intestinal capsule endoscope (ALICE) was developed by utilizing interaction between a permanent magnet and magnetic A novel robotic capsule endoscope equipped with a biopsy module for intestinal tissue extraction is presented.

Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call