Abstract

Any increase in perforations in surgical gloves is a concern. We conducted a prospective study to find a clinically acceptable brand of latex-free gloves suitable for orthopaedic surgery. Five different brands of gloves approved for use were selected. Two of the latex-free gloves were rejected as their clinical usability in arthroplasty was poor. The Cardinal Esteem latex-free glove has a smooth surface and was slippery, especially in total knee arthroplasty. The Biogel Skin Sense under glove was found to be unacceptably thick, affecting both surgical dexterity and tactility. The three remaining gloves were Biogel latex (control), Synthesis Polyco (latex-free) and Cardinal Esteem SMT (latex-free). Gloves were then collected for testing from 241 arthroplasties. Gloves used for primary knee/hip replacements were tested using a validated water distension test. Latex-free gloves were found to have higher perforation rates compared to latex. Our study demonstrates that currently available latex-free gloves have inferior clinical performance and are not recommended for use in arthroplasty surgery.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.