Abstract

The film effectiveness and coolant jet temperature profile on the suction side of a gas turbine blade were measured using a transient liquid crystal and a cold-wire technique, respectively. The blade has only one row of film holes oear the gill hole portion on the suction side of the blade. Tests were performed on a five-blade linear cascade in a low-speed wind tunnel. The mainstream Reynolds number based on cascade exit velocity was 5.3×105. Upstream unsteady wakes were simulated using a spoke-wheel type wake generator. Coolant blowing ratio was varied from 0.6 to 1.2. Wake Strouhal number was kept at 0 and 0.1. Results show that unsteady wake reduces film cooling effectiveness. Results also show that film injection enhances local heat transfer coefficient while the unsteady wake promotes earlier boundary-layer transition. The development of coolant jet temperature profiles could be used to explain the film cooling performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.