Abstract
Over the past 18 months different lots of [1,2-3H]cholesterol and [24,25-3H]cholesterol were found to be radiochemically acceptable by conventional chemical and other in vitro tests, yet, when co-administered with [4-14C]cholesterol to human subjects, an abrupt fall in the 3H/14C specific activity ratio in plasma cholesterol was discovered in every case. We have concluded that all batches of [3H]cholesterol should be regarded as radiochemically unreliable unless they are shown to behave identically in all respects to [4-14C]cholesterol in an appropriate in vivo assay system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings of the National Academy of Sciences of the United States of America
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.