Abstract

Unlike traditional coal-powered energy generation, renewable energy sources do not generate carbon dioxide emissions. To enhance the efficiency of renewable energy systems, energy storage systems (ESSs) have been implemented. However, in South Korea, ESS fire incidents have emerged as a significant social problem. Consequently, a government-formed committee was established to investigate the cause of these fires through the analysis of the data collected from ESSs, stored in the battery management system (BMS) log data of the fire-resistant safe storage. In the first phase of the investigation, the committee was unable to identify the underlying characteristic of ESS fires. Nevertheless, in the second phase, the investigation committee could identify the key characteristics of ESS fires by analyzing the BMS log data. ESS fires were found to occur when the state of charge level was more than 95% and during the initiation of thermal runaway in specific cells. Despite these findings, the committee was unable to determine the root cause of ESS fires.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.