Abstract

Abstract The article discusses the universal current sensor fault detection and compensation mechanism, which can be applied in three-phase power electronics (PE) symmetrical system. The mechanism is based on the assumption that a symmetrical system can be described using different components in the stationary reference frame. The solution given in article as a Cri-base detector was tested in electrical drives with induction motors (IMs) and permanent magnet synchronous motors (PMSMs). This study also proves that the same algorithm can work stable in active rectifier systems. Such an application of this detector has not been previously reported in the literature. The article describes the detection of various types of faults in different phases. The fault-tolerant voltage-oriented control (FTVOC) of an active rectifier is compared with previously described solutions for IMs and PMSMs. By analysing in various types of systems, the work proves the universality of the detector based on Cri markers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.