Abstract

In screening for hemoglobinopathies, high-performance liquid chromatography (HPLC) achieves excellent sensitivity and specificity, while adding the very important quantitative element to the analysis. Due to the development of a rapid, automated HPLC system, California began screening 600,000 births per year in 1990 using this method. Based on confirmatory testing for 97% of the initial positive results resulting from 2.2 million screens, HPLC has proven to be clinically accurate. In conjunction with the availability of quantitative data, HPLC provides a complete screening system, eliminating the need for a second screening test, and accurately discriminating beta thalassemia compound conditions. The large degree of ethnic diversity and high birth rate in California have produced detailed and reliable birth prevalence rates for most conditions and ethnicities.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.