Abstract

Understanding damage mechanisms and associated facility challenges for curtain wall systems with different boundary conditions is critical in their performance evaluation and selection during the design stage of a building's lifecycle, in particular if vulnerable to earthquake effects. While many different styles and configurations exist, limited research has been conducted on unitized four-sided structural sealant glazing (4SSG) with re-entrant corners under dynamic racking testing conditions. As such, this paper details a study on full-scale unitized 4SSG curtain wall system mockups featuring a re-entrant corner and subjected to cyclic racking displacements. Racking tests were carried out in accordance with the American Architectural Manufacturers Association (AAMA) 501.6 protocol. Glass fallout, sealant adhesive or cohesive failure, and glass cracking failure modes were identified as limit states and corresponding drift levels were determined. Results of these tests on full-scale specimens are presented here and some of the challenges in data collection and accuracy when using a racking facility are discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.