Abstract

In domestic grid-connected PV applications, a single-phase converter is usually employed. In such low-power plants, it is possible to adopt converter topologies without galvanic isolation between the photovoltaic (PV) panels and the grid. The absence of a high- or line-frequency transformer permits us to reduce power losses, cost, and size of the converter. On the other side, in the presence of a galvanic connection, a large ground leakage current could arise due to parasitic PV panel capacitance. Leakage currents cause electric safety problems, electromagnetic interference increase and, consequently, a reduction of the converter power quality. This paper presents a converter topology able to minimize the ground leakage current also in the case of unipolar pulsewidth modulation without increasing inductive common mode filter size and preserving efficiency. Simulations and experimental results show the feasibility of the proposed solution.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.